Type 2 Fittings 15 Maintenance Procedure - Inlet Valve If the valve will not turn on, shut off, or the refill of the cistern water is slow after the valve has been in use for some time, a replacement seal may be needed (242MP071) and can be installed as follows: 1.Turn off water supply 2. Remove water level adjustment rod from upper cap assembly as shown 3. Remove upper cap assembly by lifting arm and rotating 1/8 anticlockwise, pressing down slightly on cap. 4. Replace seal 5. Hold a cup over the uncapped valve (to prevent splashing) and turn water supply on and off to clear debris in supply. 6. Refit upper cap assembly. Make sure assembly is fully turned clockwise to the locked position or valve will not turn on. Reattach water level adjustment rod to upper assembly by snapping back in place. 7. Turn on water supply as before 1 2 3 4 5 6 Product and spare parts information can be found on the Roca website at www.uk.roca.com