C6 Electronic flush valves · Installation | 803 Sentronic-S Installation, use and maintenance 4Installation Install the batteries and place the battery case inside the valve box. (A5A9502C00 / A5A9502CM0). Attention: • Please make sure that the position of the batteries is correct. The slot of the lid should be aligned with the slot of the battery case. • Make sure that the battery case is properly sealed in order to prevent humidity from affecting the battery life. • Make sure that the battery case remains dry. Water penetration of battery case may influence the battery life and product safety. •New and old batteries should not be mixed for usage. Battery box cover 4pcs AA batte ries Slot Battery box Connect and fix AC power cable into the snap-in box (A). Then connect the terminal of the transformer (B) to the snap-in in fixing bo x.Close snap-in box and place it along the transformer. (A5A9602C00 / A5A9602CM0). Input: AC100-240V/home/webapps/asp_fr/data/asp/publications/roca-general/export-(export)/faucets-technical-manual-2016 Transformer Snap-in box Close Attention: • For your own safety, do not connect the power supply until installation is complete. • The main power supply should be installed with an appropriate thermal fuse (10-15 Amp) or other protection switches. • Should the power cable be installed following any other procedure, make sure the installation is reliable and that it ensures the insulation of the cable.