808 | C6 Electronic flush valves · Installation Sentronic-S Installation, use and maintenance Specification Model A5A9502C00 / A5A9502CM0 A5A9602C00 / A5A9602CM0 Power 4 x LR6/ 1.5V/AA alkalin e batteries AC100-240V/home/webapps/asp_fr/data/asp/publications/roca-general/export-(export)/faucets-technical-manual-2016, 50/60Hz Sensor Method Reflective infrared sensor specification Sensitive distance Detection distance should be automatically adjusted within 30-70cm * Flushing mode Intensive and water saving Manual flush Control water supply and stop water supply within 5 minute manually. Flushing Deodorizer flush Deodorizer flush should be activated one time under 3 users used in procedure consecutive 2 minutes. Self-cleaning Self-cleaning will be implemented once while this product is not used for 24 hours. Main Flush volume 3.5 l (+/- 0.5) (Dynamic pressure is 0.2 Mpa(2 bar)) Working temperature Water inlet connection G1/2” Working water pressure 0.05 - 0.7 MPa (0.5-7 bar) Product size 120 × 120 × 92 mm Product weight 2 kg (±0.5 kg) Note: *Sensor will adjust the sensitive distance automatically based on the surrounding environment. Troubleshooting Symptom Probable Cause Action 1. No batteries or wrongly installed 1. Check the batteries (A5A9502C00 / A5A9502CM0) No response 2. A/C power source outage or power cut 2. Check the power source (The indicator not on) (A5A9602C00 / A5A9602CM0) 3. Check the sundries No flushing 3. There are sundries in front of a sensor. The 4. Check the sensor window sensor window is dirty. 5. Check the wire connector 4. The wire connection is not good or wrongly connected. There is response 1. The installation is just finished. 1. Wait for 60 seconds. (The indicator flickers) 2. The inlet valve is not fully opened. 2. Fully open the inlet valve. No flushing or bad flushing result 1. The inlet valve is not opened. 1. Fully open the inlet valve. Not enough water 2. The filter is blocked. 2. Clean the filter. 3. The water pressure is too low. 3. Contact the water supplier. Water can’t stop There is dirt inside the solenoid valve. Clean the filter (The indicator not flickering) No flushing but the indicator The batteries are run out Change the batteries flickers (A5A9502C00 / A5A9502CM0) Other Please contact with dealer or call at 902400423 (Only in Spain)