830 | C6 Electronic flush valves · Installation Euret-E Installation, use and maintenance 6Installation procedure Make sure the connection is OK and open the water to test the function. After the function test is completed, follow the bottom diagram to apply silicone sealer around the urinal. • Apply silicone continuously around the top section of urinal. • Make sure there is no water leakage around the AC power socket to prevent possible installation failure. 7Working mode setup Distance adjustment Follow these steps to adjust the detection distance in reduced spaces. ENTER INTO DISTANCE LED will flash ten times and IR will ADJUSTMENT MODE automatically adjust distance Approach a magnet to IR window for >10sec NOTE: For auto-adjustment, make sure no objects are located in the detection range during the setting process. If you would like to manually adjust the distance please put an object (such us a sheet of paper) in the desired distance during the setting time. Flushing mode selection For auto-flushing mode, you may select the water-saving mode or the intensive cleaning mode based on your preferences. WATER SAVING MODE INTENSIVE CLEANING Pre-flush When the interval between two users is more than 30min Always Main flush Half-volume flush when the interval between two users is Always under 5min. Deodorizer function Not available Flush if there are more than 3 users in 2 min. WATER INTENSIVE ENTER INTO SAVING MODE CLEAN MODE FLUSHING Apply Apply MODE magnet LED will flash once magnet LED will flash two times Approach a magnet to IR window between 5-10sec Wait 10sec Finish setting 8Operational working procedure The previous flush will not be activatef if the detection time is over 2 seconds. If the detection time exceeds 7 seconds, then the main flush will take place once the user is outside the detection area. Flush activates after Detection time ≥ 7 sec user is not within sensitive range. Automatic flush 2 4h (fixed-time flushing/ automatic cleaning) Should the product not be used for a long period of time, then a full flush will be activated every 24 hours.