C6 Electronic flush valves · Installation | 805 Sentronic-S Installation, use and maintenance 6Installation Attach the outlet pipe to the outlet of the valve box. Use teflon to ensure the watertightness of the connection. Attention: • Adjust the length of the outlet pipe by cutting it according to the requirements of the product. • Ensure that the nut is firmly fixed to avoid water leaks. C onnecting pipe Outlet connector Rubber packing Nut 90° Curve pipe Cover 7Working mode setup Follow these steps to adjust the detection distance in reduced spaces. ENTER INTO DISTANCE LED will flash ten times ADJUSTMENT MODE and IR will automatically adjust distance Approach a magnet to IR window for >10 sec Note: For auto adjustment, make sure no object is located in the detection range during the process. Should you wish to adjust the distance manually please put an object (such us a sheet of paper) in the desired distance during the adjustment process. Flushing mode selection For auto-flushing mode, you may select water-saving mode or standard mode based on your preference. Water-saving mode is the default setting. W ATER SAVI NG MODE INTENSIVE CLEANING Pre-flush When the interval between two users is more than 30 min Always Main flush Half volume when the interval between two users is less than 5 min. Always Deodorizer function Not available Flush if there are more than 3 users in 2 min. WATER INTENSIVE ENTER INTO Place the SAVING Place the CLEANING FLUSHING magnet MODE magnet MODE MODE LED will flash LED will flash for Approach a magnet to IR once two times. window between 5-10 sec Wait 10 sec Finish setting