C6 Electronic flush valves · Installation | 813 Sentronic-R Installation, use and maintenance 4Installation procedure Install the batteries and place the battery case inside the valve box. (A5A9702...). Attention: • Please make sure that the position of the batteries is correct. The slot of the lid should be aligned with the slot of the battery case. • Make sure that the battery case is properly sealed in order to prevent humidity from affecting the battery life. • Make sure that the battery case remains dry. • New and old batteries should not be mixed for usage. Battery box cover 4pcs AA batteries Slot Battery box Connect and fix AC power cable into the snap-in box (A). Then connect switching the terminal of the transformer (B) into snap-in fixing box. Close snap-in box and place it along the transformer. (A5A9802...) Input : AC100-240V/home/webapps/asp_fr/data/asp/publications/roca-general/export-(export)/faucets-technical-manual-2016 Transformer Snap-in box Close Attention • For your own safety, do not connect the power supply until installation is complete. • The main power supply should be installed with an appropriate thermal fuse (10-15 Amp) or other protection switches. • Should the power cable be installed following any other procedure, make sure the installation is reliable and that it ensures the insulation of the cable.